Additional Info
FLIR G300 pt detects the following gases:
Benzene, Ethanol, Ethylbenzene, Heptane, Hexane, Isoprene, Methanol, MEK, MIBK, Octane, Pentane, 1-Pentene, Toluene, Xylene, Butane, Ethane, Methane, Propane, Ethylene and Propylene.
FLIR G300 pt: complete solution mounted on a precise pan/tilt mechanism
Whereas the FLIR G300 a and FLIR A6604 need to be integrated in a housing, the G300 pt is already integrated in a robust housing that is mounted on a pan/tilt mechanism.
It allows the user to rotate the camera 360° continuously and to tilt it +45 or -45. It allows monitoring different areas with the same system. Ideal if you want to monitor both gas leaks and use the system for predictive maintenance applications at the same time.
The Pan/Tilt has 128 preset positions. Perfect if you want to scan different areas continuously. The G300 pt is also equipped with a long range daylight/low light camera. The video output of the thermal imaging and daylight/low light camera are simultaneously available. The daylight camera offers a 36x optical zoom
Specifications
FLIR G300 pt Thermal Imaging Camera Technical Specifications
Imaging & Optical Data |
FLIR G300 pt |
IR resolution |
320 × 240 pixels |
Thermal sensitivity/NETD |
<15 mK @ +30°C (+86°F) |
Field of view (FOV) |
24° × 18° with 23 mm lens; 14.5° x10.8° with 38 mm lens |
Minimum focus distance |
0.3 m (1.0 ft.) for 23 mm lens; 0.5 m (1.64 ft.) for 38 mm lens |
F-number |
1.5 |
Focus |
Automatic using FLIR SDK or manual |
Zoom |
1–8× continuous, digital zoom |
Digital image enhancement |
Noise reduction filter, High Sensitivity Mode (HSM) |
Detector data |
Detector type |
Focal Plane Array (FPA), cooled InSb |
Spectral range |
3.2–3.4 μm |
Ethernet |
Ethernet |
Control, result and image |
Ethernet, type |
100 Mbps |
Ethernet, standard |
IEEE 802.3 |
Ethernet, connector type |
RJ-45 |
Ethernet, communication |
TCP/IP socket-based FLIR proprietary |
Ethernet, video streaming |
Two independent channels for each camera: MPEG-4, H.264 or M-JPEG |
Ethernet, image streaming |
NA |
Ethernet, protocols |
TCP, UDP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, MDNS (Bonjour), SMB/CIFS, SNTP,SMTP, DHCP, uPnP |
Composite video |
Video out |
Composite video out, PAL/NTSC compatible |
Imaging and optical data (visual camera) |
Field of view (FOV) / Focal lenghts |
57.8° (H) to 1.7° (H) / 3.4 mm (wide) to 122.4 mm (tele) |
F-number |
1.6 to 4.5 |
Focus |
Automatic or manual (built in motor) |
Optical Zoom |
36× continuous |
Electronic Zoom |
12× continuous, digital, interpolating |
Detector data (visual camera) |
Focal Plane Array (FPA) / Effective pixels |
1/4” Exview HAD CCD / 380,000 |
Technical specification (pan & tilt) |
Azimuth Range Az velocity |
360° continuous, 0.1 to 60°/sec max |
Elevation Range El velocity |
+/- 45°, 0.1 to 30°/sec. max |
Programmable presets |
128 |
Automatic heaters |
Prevent window to ice up. Switched on at +4°C (39°F). Switched off at +15°C (59°F). |
Power system |
DC operation |
24 VAC (21-30 VAC; 24 VAC: 215 VA max with heather) or 24 VDC (21-30- VDC; 24 VDC: 200 W max. with heather) |
Environmental data |
Operating temperature range |
–25°C to +50°C (–13°F to +122°F) |
Storage temperature range |
–30°C to +60°C (–22°F to +140°F) |
Humidity (operating and storage) |
IEC60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F) (2 cycl) |
Directives |
Low voltage directive:2006/95/EC, EMC:2004/108/EC, RoHS:2002/95/EC, WEEE:2002/96/EC |
EMC |
EN61000-6-2 (immunity) / EN61000-6-3 (emission) / FCC 47CFR Part 15 Class B (emission) / EN 61000-4-8, L5 |
Encapsulation |
IP 66 |
Bump |
5g, 11 ms (IEC 60068-2-27) |
Vibration |
2g (IEC 60068-2-6) |
Physical data |
Weight |
18.7 kg (41.2 lb.) |
Camera size, excl. lens (L × W × H) |
460 x 467 x 326 mm (18.1 x18.4 x 12.8 in.) |
Housing material |
Aluminum |